{"id":2530,"date":"2026-03-09T08:24:00","date_gmt":"2026-03-09T00:24:00","guid":{"rendered":"https:\/\/www.takebrakes.com\/?p=2530"},"modified":"2026-02-24T17:27:51","modified_gmt":"2026-02-24T09:27:51","slug":"how-to-calculate-industrial-brake-torque","status":"publish","type":"post","link":"https:\/\/www.takebrakes.com\/es\/how-to-calculate-industrial-brake-torque\/","title":{"rendered":"C\u00f3mo calcular el par de freno industrial: factores de seguridad, inercia y reglas de selecci\u00f3n para gr\u00faas y transportadores"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Seleccionar un freno industrial no se trata solo de elegir un modelo que \"parezca lo suficientemente grande\". Si subdimensionas el par, la carga se deslizar\u00e1 o caer\u00e1. Si lo sobredimensionas, romper\u00e1s ejes, desgastar\u00e1s dientes de engranajes y da\u00f1ar\u00e1s estructuras con golpes de parada brutales.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This article provides the <strong>engineering formulas<\/strong> y <strong>safety factors (K-factors)<\/strong> needed to size brakes correctly for hoists, travel drives, and belt conveyors. We will connect these calculations to our product lines, such as <a href=\"https:\/\/www.takebrakes.com\/es\/ywz13-series-electric-hydraulic-drum-brake\/\"><strong>YWZ13 drum brakes<\/strong><\/a> for general crane duty and <a href=\"https:\/\/www.takebrakes.com\/es\/sh-series-hydraulic-fail-safe-disc-brakes\/\"><strong>SH fail-safe disc brakes<\/strong><\/a> for high-energy holding.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Infograf\u00eda que muestra las entradas de la f\u00f3rmula: Potencia del motor (P), Velocidad (n) y Factor de Seguridad (K).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-1-the-fundamental-torque-formula\">1) La f\u00f3rmula fundamental del par<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Comienza con el par est\u00e1tico requerido para mantener la potencia nominal del motor. La ecuaci\u00f3n que rige es:<\/p>\n\n\n<span class=\"katex-eq\" data-katex-display=\"true\">$T_{est\u00e1tico} = \\frac{9550 \\times P}{n}$<\/span>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>$T_{est\u00e1tico}$:<\/strong> Par nominal del motor (N\u00b7m)<\/li>\n\n\n\n<li><strong>$P$:<\/strong> Potencia del motor (kW)<\/li>\n\n\n\n<li><strong>$n$:<\/strong> Velocidad del eje del freno (rpm) \u2014 <em>Crucial: \u00a1Esta es la velocidad en el freno, no la salida de la caja de cambios!<\/em><\/li>\n\n\n\n<li><strong>9550:<\/strong> Conversi\u00f3n constante de kW\/rpm a N\u00b7m.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Ejemplo:<\/strong> A 45 kW motor running at 750 rpm (common for crane hoists):<\/p>\n\n\n<span class=\"katex-eq\" data-katex-display=\"true\">$T_{est\u00e1tico} = \\frac{9550 \\times 45}{750} = 573\\ \\text{N\u00b7m}$<\/span>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Note: This is just to hold the motor against its own rating. It does not account for gravity, safety, or dynamic stopping.<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-applying-the-safety-factor-k\">2) Aplicando el Factor de Seguridad ($K$)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">You never select a brake at $T_{static}$. You apply a <strong>Service Factor ($K$)<\/strong> based on the risk and application type.<\/p>\n\n\n<span class=\"katex-eq\" data-katex-display=\"true\">$T_{freno} \\ge T_{est\u00e1tico} \\times K$<\/span>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Aplicaci\u00f3n<\/th><th>Factor $K$ recomendado<\/th><th>\u00bfPor qu\u00e9?<\/th><\/tr><\/thead><tbody><tr><td><strong>Levantamiento (Polipasto)<\/strong><\/td><td><strong>$K \\ge 2.0$<\/strong> (A menudo 2.5 para metal fundido)<\/td><td>La gravedad es constante. Si la fricci\u00f3n disminuye (desgaste\/desgaste), necesitas una capacidad de reserva del 100% para prevenir una ca\u00edda.<\/td><\/tr><tr><td><strong>Viaje \/ Traves\u00eda<\/strong><\/td><td><strong>$K \\approx 1.5 \u2013 2.0$<\/strong><\/td><td>Para detenerse dentro de los l\u00edmites del viento pero evitar el deslizamiento de la rueda. Demasiado par ($K&gt;2.5$) causa bloqueo de la rueda y desgaste del riel.<\/td><\/tr><tr><td><strong>Transportadores de banda<\/strong><\/td><td><strong>$K \\approx 1.5 \u2013 2.0$<\/strong><\/td><td>Previene el retroceso en correas inclinadas. La capacidad t\u00e9rmica (tiempo de parada) suele ser m\u00e1s cr\u00edtica que el par.<\/td><\/tr><tr><td><strong>Winches (Con conductor)<\/strong><\/td><td><strong>$K \\ge 3.0$<\/strong> (A menudo se requieren frenos duales)<\/td><td>Requisito extremo de seguridad.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Applying to our Example (Hoist):<\/strong>\n<br>Required Brake Torque = $573\\ \\text{N\u00b7m} \\times 2.0 = 1146\\ \\text{N\u00b7m}$.\n<br>You would select a brake rated for at least <strong>1200 N\u00b7m<\/strong> (e.g., a YWZ13-315 or YWZ13-400 model depending on thruster).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-thermal-capacity-the-hidden-killer\">3) Capacidad t\u00e9rmica: El asesino oculto<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Calculated torque ensures you can <em>hold<\/em> the load. But can you <em>stop<\/em> it without burning the linings?<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-stopping-energy-calculation\">C\u00e1lculo de energ\u00eda de parada<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Cada vez que te detienes, la energ\u00eda cin\u00e9tica se convierte en calor.\n<br>Energ\u00eda ($E$) por parada (Julios):<\/p>\n\n\n<span class=\"katex-eq\" data-katex-display=\"true\">E = \\frac{1}{2} J \\omega^2<\/span>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>$J$:<\/strong> Inercia total del sistema reflejada en el eje del freno (kg\u00b7m\u00b2).<\/li>\n\n\n\n<li><strong>$\\omega$:<\/strong> Velocidad angular (rad\/s) = $rpm \\times \\frac{2\\pi}{60}$.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">If $E$ exceeds the brake&#8217;s thermal rating (kJ per hour), the linings will glaze and fade.\n<br><strong>Regla mnem\u00f3nica:<\/strong> For high-inertia loads (conveyors, large fans), verify the <strong>thermal capacity<\/strong> of the disc\/drum, not just the torque. You may need a <strong>ventilated disc<\/strong> (<a href=\"https:\/\/www.takebrakes.com\/es\/sh-series-hydraulic-fail-safe-disc-brakes\/\">SH series<\/a>) or a larger drum size just to dissipate heat.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-4-stopping-time-check\">4) Verificaci\u00f3n del tiempo de parada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u00bfLa m\u00e1quina se detendr\u00e1 lo suficientemente r\u00e1pido?\n<br>Tiempo de desaceleraci\u00f3n ($t$):<\/p>\n\n\n<span class=\"katex-eq\" data-katex-display=\"true\">t = \\frac{J \\times n}{9.55 \\times (T_{freno} \\pm T_{carga})}<\/span>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>$T_{freno}$:<\/strong> Configuraci\u00f3n real del par.<\/li>\n\n\n\n<li><strong>$T_{carga}$:<\/strong> Par de carga que ayuda ( ) o resiste (-) la parada.<\/li>\n\n\n\n<li><strong>Resultado:<\/strong> Si $t$ es demasiado largo (&gt; 3-5s para polipastos), se compromete la seguridad. Si es demasiado corto (&lt; 0.5s para viaje), las cargas de choque romper\u00e1n componentes.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-5-selecting-the-right-brake-series\">5) Selecci\u00f3n de la serie de frenos adecuada<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Una vez que tengas los n\u00fameros, elige el hardware:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Serie<\/th><th>Tipo<\/th><th>Rango de par<\/th><th>Mejor para<\/th><\/tr><\/thead><tbody><tr><td><a href=\"https:\/\/www.takebrakes.com\/es\/ywz13-series-electric-hydraulic-drum-brake\/\"><strong>YWZ13 \/ YWZ<\/strong><\/a><\/td><td>Tambor electrohidr\u00e1ulico<\/td><td>100 \u2013 12,500 N\u00b7m<\/td><td><strong>Gr\u00faas generales:<\/strong> Puentes EOT, gr\u00faas, polipastos generales. Robustos, f\u00e1cil mantenimiento.<\/td><\/tr><tr><td><a href=\"https:\/\/www.takebrakes.com\/es\/sh-series-hydraulic-fail-safe-disc-brakes\/\"><strong>SH \/ SB<\/strong><\/a><\/td><td>Disco hidr\u00e1ulico<\/td><td>500 \u2013 30,000  N\u00b7m<\/td><td><strong>De servicio pesado:<\/strong> Paradas a alta velocidad, transportadores, gr\u00faas portacontenedores. Mejor disipaci\u00f3n t\u00e9rmica.<\/td><\/tr><tr><td><a href=\"https:\/\/www.takebrakes.com\/es\/se-series-electromagnetic-fail-safe-brake\/\"><strong>SE \/ DC<\/strong><\/a><\/td><td>Disco electromagn\u00e9tico<\/td><td>5 \u2013 500 N\u00b7m<\/td><td><strong>Precisi\u00f3n\/Peque\u00f1o:<\/strong> Herramientas de m\u00e1quina, montaje en escenario, peque\u00f1os polipastos. Respuesta r\u00e1pida.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-6-common-selection-pitfalls\">6) Errores comunes en la selecci\u00f3n<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Ignorando la eficiencia de la caja de cambios:<\/strong> Si el freno est\u00e1 en el eje de alta velocidad, la resistencia de la caja de cambios ayuda a detenerse. Si est\u00e1 en el eje de baja velocidad (freno de seguridad), no.<\/li>\n\n\n\n<li><strong>Sobrecarga en los accionamientos de viaje:<\/strong> Seleccionar $K=3.0$ para un accionamiento de viaje de puente de gr\u00faa garantiza el deslizamiento de las ruedas y cargas oscilantes. Usa $K=1.5$ o un freno de par variable.<\/li>\n\n\n\n<li><strong>Desajuste de voltaje:<\/strong> Calcular el par perfectamente, pero ordenar el voltaje del accionador equivocado (380V vs 415V vs 460V) significa que el proyecto se detiene en la instalaci\u00f3n.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-need-help-sizing-your-brake\">\u00bfNecesitas ayuda para dimensionar tu freno?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Deja de adivinar. Env\u00edanos la potencia de tu motor (kW), velocidad (rpm) y tipo de aplicaci\u00f3n (polipasto\/viaje). Nuestro equipo de ingenier\u00eda realizar\u00e1 el c\u00e1lculo, recomendar\u00e1 el Factor de Seguridad correcto ($K$) y seleccionar\u00e1 el modelo de freno \u00f3ptimo para tu proyecto.<\/p>","protected":false},"excerpt":{"rendered":"<p>Selecting an industrial brake isn&#8217;t just about picking a model that &#8220;looks big enough.&#8221; If you undersize the torque, the load will drift or drop. If you oversize it, you&#8217;ll snap shafts, strip gear teeth, and damage structures with brutal stop shocks. This article provides the engineering formulas and safety factors (K-factors) needed to size [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5,3],"tags":[],"class_list":["post-2530","post","type-post","status-publish","format-standard","hentry","category-info","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/posts\/2530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/comments?post=2530"}],"version-history":[{"count":1,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/posts\/2530\/revisions"}],"predecessor-version":[{"id":2531,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/posts\/2530\/revisions\/2531"}],"wp:attachment":[{"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/media?parent=2530"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/categories?post=2530"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.takebrakes.com\/es\/wp-json\/wp\/v2\/tags?post=2530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}